Wapiti Acid Gas Capture & Sequestration
![Wapiti Gas Processing Acid Gas (CO2 & H2S) Capture and Sequestration](https://equinox-eng.com/wp-content/uploads/2022/02/wapiti-Cropped.jpg)
Client:
Energy Transfer
Location:
Western Canada
Project Summary:
Equinox delivered Concept, FEED, Detail Design and installation of Gas Processing Facility (200 MMscfd) utilizing amine solvent-based capture to separate acid gas stream (90% H2S, 10% CO2). The operation includes acid gas compression, dehydration and blending – allowing for dual mode (acid gas injection or blending into pipeline to sulphur plant). The liquids recovery system captures 3,500 bpd C5+ condensate and 2,500 bpd C3+ NGL for sales.
Overview:
- Inlet Separation
- Heat Medium system
- Amine-based CO2, H2S capture system
- Acid gas compression, pumping
- Acid Gas Dehydration
- Acid gas injection or blending
- Propane refrigeration
- Mercaptans removal
- Utilities
Scope of Work:
- FEED, Detail Design Engineering
- Technology Selection
- Equipment Specification
- Facility Layout & Modeling
- Key Engineering Drawings
- HAZOP & Safety Workshops
- Procurement
- Commissioning & Start-up