Power Plant - Carbon Capture, Transportation and Sequestration (1.7 mtpa)
Client:
Long Ridge Energy
Location:
Ohio, USA
Project Summary:
Equinox delivered this Conceptual Study for existing Gas Turbine Power Generation Facility treating 1.7 Bcf of exhaust gas to recover 76 MMscfd of 96% CO2.
The new facility will capture 1.6 mtpa of CO2, utilizing a post-combustion capture scheme. Primary components include inlet cooling tower, formulated amine CO2 recovery technology, intercooled and injection compression. Captured CO2 is processed to more than 90% purity prior to dehydration. The captured CO2 would be compressed (centrifugal), dehydrated (TEG dehydration) and sent to a transportation pipeline for Enhanced Oil Recovery.
Overview:
- Flue Gas Blower, Cooler
- Quench System
- Heat Medium system
- Amine-based CO2 capture system
- EMD Centrifugal compression
- TEG Dehydration
- Amine Reclaimer system
- Wastewater system
- Utilities
Scope of Work:
- Conceptual Study Engineering
- Technology Evaluation
- Equipment Evaluations
- Process Simulations
- Facility Layout & Modeling
- Key Engineering Drawings
- Economic Modeling
- CAPEX, OPEX Estimating